SX
™
Service and Maintenance Manual 3-43 960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
ELECTRICAL COMPONENTS
RED RELAY 24V (con’t)
There are no adjustments necessary on the Red
Relay.
1. Remove the six screws holding the Frame
Cover, Set screws and Frame Cover aside
(Figure 3-113).
2. With a small screwdriver, remove all
connections from Red Relay.
3. Using the same screwdriver, pull the DIN
release tab out and pivot Relay up and towards
you (Figure 3-114).
4. Remove Relay.
5. Snap replacement Relay onto DIN rail with the
Red LED closest to you.
6. Reconnect all wires (Table 3-3).
Table 3-3. Red Relay connections
Wire Label
Wire Color
Terminal
Number
X7
Dark Blue
1
92
Dark Blue
2
-
Red
3
-
White & Blue
4
ADJUSTMENT
REPLACEMENT
Figure 3-113. Frame Cover Screws
Figure 3-114. Remove Red Relay