SX
™
Service and Maintenance Manual 3-37 960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
ELECTRICAL COMPONENTS
SOLID STATE RELAY (con’t)
2. Set your DVOM to a range capable of
measuring 120 VAC. With one probe, contact
pin number 1, with the other probe, contact pin
number 2 (Figure 3-101). 120 VAC should be
shown. If 0 VAC is shown, refer to the section
on testing the Seal Wire Transformer.
3. If nothing is found wrong with the Seal Wire
Transformer, the relay is defective and will
require replacement.
Figure 3-101. Testing 120VAC on Solid State Relay