SX
™
Service and Maintenance Manual 3-38 960714-02B © 2007 I2407
SECTION 3 – COMPONENT REPAIR
ELECTRICAL COMPONENTS
SOLID STATE RELAY (con’t)
There are no adjustments necessary on the Solid
State Relay.
1. Remove the four screws holding the Load
Plate, set Load Plate aside (Figure 3-102).
2. Locate Solid State Relay; remove clear plastic
cover (Figure 3-103).
3. Remove the four wire screws.
4. Remove the two screws holding the Solid State
Relay to the Base Plate and set aside.
5. Remove defective relay.
6. Orientate replacement Solid State Relay so
that connections 3 and 4 are towards the front
of the machine.
7. Screw Solid State Relay down onto Base Plate.
8. Reconnect the four wires and tighten holding
screws (Table 3-1).
9. Snap clear plastic cover over Solid State
Relay.
10. Reattach Load Plate using screws and locking
washers.
Wire Label
Wire Color
Terminal Number
-
Black
1
-
Black
2
91
Dark Blue
3
Y6
Dark Blue
4
ADJUSTMENT
REPLACEMENT
Figure 3-102. Load Plate Screws
Figure 3-103. Solid State Relay with cover
Table 3-1. Solid State Relay connections
Always remove electrical power from the
SX
prior to performing any maintenance
on the machine.
WARNING