AR-BC320 TROUBLESHOOTING 11 - 21
Main
code
Sub
code
Title
Paper feed motor lock trouble
L4
02
Display
Lamp/Message
Phenomenon Detail
In warm-up, or in canceling
a jam, the paper feed
motor is rotated, and the
lock signal is not detected
within 1sec.
Section
Paper feed
Case 1
Cause
Paper feed motor trouble,
disconnection of the
harness between the PCU
PWB and the paper feed
motor, control circuit
trouble
Check &
Remedy
Use SIM 6-1 to check the
paper feed motor
operation. Check the
harness and the connector
between the PCU PWB
and the paper feed motor.
Main
code
Sub
code
Title
Transfer belt lift motor trouble
L4
06
Display
Lamp/Message
Phenomenon Detail
When the belt motor lifts
up or down, the change in
the belt home position
sensor characteristics is
not detected within the
specified time.
(When the motor lifts up,
the lower limit sensor
remains ON after the
specified time.)
(When the motor lifts
down, the lower limit
sensor does not turn on
after the specified time.)
Section
Paper feed
Case 1
Cause
Belt lift motor trouble,
disconnection of the
harness between the PCU
PWB and the belt lift
motor, control circuit
trouble
Check &
Remedy
Use SIM 6-1 to check the
belt lift motor operation.
Check the harness and the
connector between the
PCU PWB and the belt lift
motor.
Main
code
Sub
code
Title
Transfer belt motor trouble
L4
07
Display
Lamp/Message
Phenomenon Detail
1) Before driving the drum,
the calibration plate is
opened with the
process control BK
sensor, and light is
emitted with the gain
value of 0 and with the
light emitting quantity
fixed to 120. The
average of ten light
quantities repeats to be
5 or less for 3 times
continuously.
2) Immediately after
driving the drum, the
calibration plate is
opened with the
process control BK
sensor, and one whole
turn of the belt surface
is scanned with the gain
value of 0 and with the
light emitting quantity at
the optimum value (120
– 50). The difference
between the max. value
and the min. value of
the scanned data is 5 or
less.
Section
Paper feed
Case 1
Cause
Transfer belt motor
connector disconnection,
process control sensor
connector disconnection,
process control BK sensor
defect, defective
connection of the harness
between the PCU PWB
and the transfer belt motor,
defective control circuit
Check &
Remedy
Check the transfer belt
motor operation with
SIM25-1. Check the
process control sensor
operation with SIM44-2.
Check the harness and the
connector between the
PCU PWB and the transfer
belt motor.