With the exception of
Error Class 8 = Other Error, the error class is generated by the fieldbus pcb
communications software if communication is faulty. All return codes supplied by the inverter system
come under
Error Class 8 = Other Error. A more detailed breakdown of the error is obtained from the
Additional Code element.
5.5.2
Error Code
The Error Code element provides a more detailed analysis of the cause of the error within the error
class. The error code is described in DIN 19245 Part 2 (Section 3.16.1.4.4). The error code is
generated by the fieldbus pcb communications software if communication is faulty. In the case of
Error Class 8 = Other Error, only Error Code = 0 (Other Error Code) is defined, with a detailed
breakdown provided in
Additional Code.
5.5.3
Additional Code
The Additional Code contains the SEW-specific return codes for faulty inverter parameter adjustment.
They are returned to the master under
Error Class 8 = Other Error.
Add. code
high (hex)
Add. code
low (hex)
Meaning
00
10
Illegal parameter index
00
11
Function/parameter not implemented
00
12
Access is read only
00
13
Parameter lock active (P800)
00
14
Factory setting active (P830)
00
15
Parameter value too large
00
16
Parameter value too small
00
17
Necessary option pcb for this function/parameter not installed
00
18
Error in system software
00
19
Parameter access via this serial interface not permitted
00
1A
Speed control active (P770)
00
1B
Unauthorized access
00
1C
Output stage not disabled
00
1D
Invalid parameter value (e.g. invalid intermediate value)
00
1E
Factory setting started
00
22
4Q-operation 1 (P890) required, e.g. for hoist function 1 (P710)
00
23
4Q-operation 2 (P891) required, e.g. for hoist function 2 (P712)
00
24
DC braking 1 active (P730), modification not possible
00
25
DC braking 2 active (P733), modification not possible
00
26
Hoist function set 1 active (P710), modification not possible
00
27
Hoist function set 1 active (P730), modification not possible
00
28
Parameter not memory-resident; lost in case of power down
00
29
Parameter access via this serial interface not permitted
00
2A
Speed control not active (P770)
00
2B
Controller inhibit required
00
2C
Motor size-up 1 (P328) and rapid start 1 (P720) cannot be activated at the same time
00
2D
Motor size-up 2 (P348) and rapid start 2 (P723) cannot be activated at the same time
00
2E
Necessary option pcb for this function/parameter not installed
00
2F
4Q-operation 1 (P890) and DC braking 1 (P730) cannot be activated at the same time
00
30
4Q-operation 2 (P891) and DC braking 2 (P733) cannot be activated at the same time
00
31
Controller inhibit active, modification not possible
00
32
Synchronous operation not active (P760)
00
33
Synchronous operation: MOVITRAC is slave (P761)
00
34
Invalid parameter frame type
5
Setting Inverter Parameters
MOVITRAC
®
31.. Fieldbus Unit Profile
51