8
Service
MOVIFIT® compact error list
Operating Instructions – MOVIFIT
®
compact
89
8.2.2
Error list for MOVIFIT
®
compact motor starter
Code Subcode Meaning
Possible cause
Measure
F 01
3
Overcurrent at motor ter-
minal X9
(Reversing starter/dual-mo-
tor starter, motor 1)
Short circuit at
starter output
•
Check the connection between the
starter output and the motor.
•
Check the motor winding for short
circuiting.
Sudden overload
of motor
•
Check motor shaft for blocking.
4
Overcurrent at motor ter-
minal X8
(Dual-motor starter, motor
2)
Short circuit at
starter output
•
Check the connection between the
starter output and the motor.
•
Check the motor winding for short
circuiting.
Sudden overload
of motor
•
Check motor shaft for blocking.
F 06
1, 2
Phase failure during initial-
ization
Failure of one or
more line phases
•
Check the supply system cable for
phase failure.
Motors not con-
nected correctly
•
Check whether the motors are con-
nected correctly.
F 18
13, 103
CPU error
-
•
Reset the error.
•
If the error persists, contact SEW-
EURODRIVE Service.
F 25
0, 5, 7, 8,
203
EEPROM error
-
•
Load the factory settings and re-
parametrize the device.
F 34
1
Start time monitoring error
(Reversing starter / dual-
motor starter, motor 1)
Insufficient accel-
eration power
Too much load
•
Check the motor phases. Reduce the
load.
2
Start time monitoring error
(Dual-motor starter, motor
2)
Insufficient accel-
eration power
Too much load
•
Check the motor phases. Reduce the
load.
F 36
0
MBBG11A timeout error
MBBG11A dis-
connected during
manual opera-
tion.
•
Plug in the plug connector of the MB-
BG11A operator panel again.
•
Reset the error.
F 37
0
Starter software run-time
error
•
Contact SEW‑EURODRIVE Service.
F 43
0
Internal communication
error
Communication
problem between
internal control
section and
power section.
•
Contact SEW‑EURODRIVE Service.
F 44
100
Device overload (I
2
t)
Device overload
(I
2
t)
•
Reduce the drive load.
•
Avoid enabling both drives at the
same time.
F 45
17, 20
Initialization error,
power section assignment
Internal power
section not com-
patible
•
Contact SEW‑EURODRIVE Service.
22527060/EN – 08/2017