6
Startup
Parameter list of the MOVIFIT® compact inverter
Operating Instructions – MOVIFIT
®
compact
62
MOVITOOLS
®
MotionStudio
parameter no.
MBBG11A /
parameter no.
Display
Index
dec.
Su-
binde
x
dec.
Name
Range of values Factory
setting
0__
Display values
-
-
8642
0
Nominal speed
[min
-1
]
-
-
10546 13
Nominal power
[kW]
08_
Fault memory
080
99
8366
0
Error code T0
1)
[Code]
103
9304
0
Sub-error code T0
[Code]
107
8883
0
Internal error T0
[Code]
081
-
8367
0
Error code T1
1)
[Code]
-
9305
0
Sub-error code T1
[Code]
-
8884
0
Internal error T1
[Code]
082
-
8368
0
Error code T2
1)
[Code]
-
9306
0
Sub-error code T2
[Code]
-
8885
0
Internal error T2
[Code]
083
-
8369
0
Error code T3
1)
[Code]
-
9307
0
Sub-error code T3
[Code]
-
8886
0
Internal error T3
[Code]
1) The MBBG11A operator panel only displays the last error. MOVITOOLS® MotionStudio displays the last 4 errors.
MOVITOOLS
®
MotionStudio
parameter no.
MBBG11A /
parameter no.
Display
Index
dec.
Su-
binde
x
dec.
Name
Range of values Factory
setting
1__
Setpoints / ramp generators
13_
Speed ramps
130
8807
0
Ramp up
0.125 – 1500 s
1)
1 s
131
8808
0
Ramp down
0.125 – 1500 s
1)
1 s
17_
Fixed setpoints
170
xx
n
8489
0
Fixed setpoint n1
15 – 6000 min
-1
15 min
-1
171
8490
0
Fixed setpoint n2
15 – 6000 min
-1
250 min
-1
172
8491
0
Fixed setpoint n3
15 – 6000 min
-1
750 min
-1
173
10096 31
Fixed setpoint n4
15 – 6000 min
-1
1500 min
-1
1) The ramp time relates to a setpoint jump of 1500 rpm.
MOVITOOLS
®
MotionStudio
parameter no.
MBBG11A /
parameter no.
Display
Index
dec.
Su-
binde
x
dec.
Name
Range of values Factory
setting
3__
Motor parameters
30_
Limits 1
22527060/EN – 08/2017