7
Operation
Manual operation with the MBBG11A operator panel
Operating Instructions – MOVIFIT
®
compact
83
7.4.3
Manual operation in binary signal specification mode
Control the MOVIFIT
®
compact drive in binary signal specification mode as follows:
1. Open “Binary signal specification mode” as described in chapter “Activating
manual operation”.
ð
Control in “Binary signal specification mode” is now operational (STOP mode).
ð
The numbers in the 7-segment display flash.
2. Activate manual operation using the <RUN> key (RUN mode).
ð
The dots and the segments of the currently selected digital input flash in the
display.
3. Control the individual digital inputs as follows:
DI.. = 1
DI.. = 0
DI01
DI02
DI03
DI00
Enter
18500243467
Switch between the individual digital inputs using the <ENTER> key. The respective
selected digital input flashes.
•
Set the selected digital input using the <UP> key.
If “1” flashes in the display, the digital input is set (= 1).
•
The selected digital input is reset using the <DOWN> key.
If “0” flashes in the display, the digital input is not set (= 0).
Deactivating manual operation
WARNING
Risk of crushing due to unexpected start-up of the drive. The signals of the higher-
level controller are effective immediately when automatic operation is activated. The
drive runs with the speed that is specified by the higher-level controller.
Severe or fatal injuries.
•
Ensure that no persons are present in the hazard zone of the drive.
•
Before you activate automatic operation with the <RUN> key, you must set the
signals of the higher-level controller so that the drive does is not enabled.
Deactivate manual mode as follows:
1. Stop the drive with the <STOP/RESET> key.
2. Deactivate manual operation using the <OUT> key.
3. Activate automatic operation using the <RUN> key.
22527060/EN – 08/2017