5
Electrical installation
Power bus connection (line cable)
Operating Instructions – MOVIFIT
®
compact
25
5.5
Power bus connection (line cable)
WARNING
Electric shock due to dangerous voltages in the ABOX.
Severe or fatal injuries.
•
De-energize the MOVIFIT
®
device. Observe the minimum switch-off time after
disconnection from the supply system:
–
1 minute
WARNING
Electric shock due to connecting or disconnecting plug connectors when voltage is
applied.
Severe or fatal injuries.
•
Disconnect all supply voltages.
•
Make sure that the device is de-energized.
•
Never plug or unplug the plug connectors while they are energized.
WARNING
Danger of burns due to hot surfaces of the device (e.g. the heat sink).
Serious injuries.
•
Do not touch the device until it has cooled down sufficiently.
Connect the MOVIFIT
®
compact device to the power bus as follows.
1. Loosen the 4 screws and remove the EBOX from the ABOX.
X22
X23
X50
DI02
AS-I Status
DI03
Diagnose
STATU
S
AS-Interface
X21