6
Startup
Parameterization with the MBBG11A operator panel
Operating Instructions – MOVIFIT
®
compact
52
6.6
Parameterization with the MBBG11A operator panel
6.6.1
MBBG11A operator panel description
Function
You can start up, parameterize, and control MOVIFIT
®
compact devices in manual
mode with the MBBG11A operator panel. In addition to that, the keypad displays im-
portant information about the state of the drive.
Features
•
7-segment display
•
Setpoint adjuster/potentiometer (only for inverters in setpoint adjuster mode)
•
Navigation bar for displaying the current menus and the operating mode
•
6 keys for menu guidance, executing functions, and for setting parameters
•
Connection cables
Key assignment
The following illustration shows the key assignments of the MBBG11A operator panel:
Enter
out
STOP
RESET
RUN
max
0/-n
max
+n
Par
max
n
xx
n
17186799371
Key
<UP>
•
Select an icon
•
Increase value
Key
<DOWN>
•
Select an icon
•
Decrease value
Key
out
<OUT>
•
Deactivate icon
•
Exit Parameter menu
Key
Enter
<ENTER>
•
Activate icon
•
Open parameter menu
Key
RUN
<RUN>
•
Start bus/automatic mode
•
Enable drive in manual mode
Key
STOP
RESET
<STOP/RESET>
•
Stop drive
•
Reset error
22527060/EN – 08/2017