6
Startup
Assigning the AS-Interface slave address
Operating Instructions – MOVIFIT
®
compact
50
6.5
Assigning the AS-Interface slave address
SEW-EURODRIVE delivers MOVIFIT
®
compact with AS-Interface with the address 0.
The following options are available for assigning the AS-Interface address of the
MOVIFIT
®
compact (address 1A – 31A and 1B – 31B):
•
Automatic address assignment
within a configured AS-Interface system after re-
placing a MOVIFIT
®
compact drive.
The following prerequisites must be fulfilled:
– The new MOVIFIT
®
compact drive must have the address 0.
– If you replace several MOVIFIT
®
compact drives, they must be replaced indi-
vidually one after the other.
•
Manual address assignment via the plant master
Connect the drives to the AS-Interface cable one after another. This prevents sev-
eral MOVIFIT
®
compact drives from being given the same AS-Interface address.
•
Manual address assignment using a hand-held AS-Interface programming
device
When connecting the MOVIFIT
®
compact drive to the AS-Interface cable, pay at-
tention to the information in the following chapter.
22527060/EN – 08/2017