Manual – MOVI-PLC® Application Solution "SyncCrane"
89
7
Operation of auxiliary drives
Auxiliary Drive (Auxiliary Axis)
7.4
Operation of auxiliary drives
7.4.1
Starting the drive
After the download, switch to the monitor of the
Auxiliary axis
application module.
Operating modes
(fieldbus control)
Operating mode
PO1:13
PO1:12
PO1:11
Description
Default
0
0
0
No axis is moved.
Jog mode
0
0
1
•
Individual axes or the group can be moved via
the Jog+ and Jog- inputs.
•
Specify the following values:
•
Process output data words
•
Travel parameters
•
Velocity
•
Ramp
If no velocity is specified, the axis will move at
0.2 rpm.
Referencing mode
0
1
0
•
The IPOS encoder position is referenced
when start is set.
•
Reference travel establishes the reference
point (machine zero) for positioning
operations.
Positioning mode
0
1
1
•
The referenced single axis can be moved
once a target position is specified and start is
set.
•
Specify the process output data words, travel
parameters, velocity, and ramp. If no velocity
is specified, the axis will move at 0.2 rpm.