Manual – MOVI-PLC® Application Solution "SyncCrane"
57
6
Jog mode – unsynchronized
Operation
Axis number
PO3 Broadcast 99 or single axis mode 1 ... 12
Velocity specification
PO8 in [rpm] or [user units]
Velocity limit
Startup parameter
Overlapping
Startup parameter
Position limiting
Software limit switch startup parameter
Ramp specification
PO9 Acceleration ramp in [ms]
PO10 Deceleration ramp in [ms]
Brief description
After selecting a direction of rotation, the single axis (PO3 1 ... 4) or the
entire axis system (PO3 = 99) can be operated in jog mode. If software
limit switches were assigned, the travel range is restricted to these limits.
Prerequisite
•
Operating mode is selected
•
Drive is enabled
Functional
description
The direction is selected using Jog+ or Jog-.
If the software limit switch right is set > software limit
switch left, the travel range is limited to 3 position
windows (startup) before the respective software limit
switch.
If the Disable SWLS bit is set, the limitation of the
travel range is deactivated.
For the travel movement, positioning indirectly takes
place to the external encoder.
Without evaluation the limit switches, the axis can be
moved endlessly.
The drive stops with position control if the direction
selection is not enabled or both directions are
selected at the same time.
The specified ramp time is used for accelerating/
decelerating the drive.
The specified velocity of the jog mode is compared to
the velocity limit and limited if necessary.
Interface description