22
Manual – MOVI-PLC® Application Solution "SyncCrane"
3
Process data assignment
Project Planning
Expanding the process data words to a number of 32 means the following single-axis
positions are transferred:
3.5.1
Process output data words
The process output data words are assigned as follows:
PI= Process input data
PI11
Actual position axis 1 positioning mode high
PI12
Actual position axis 1 positioning mode low
PI13
Actual position axis 2 positioning mode high
PI14
Actual position axis 2 positioning mode low
PI15
Actual position axis 3 positioning mode high
PI16
Actual position axis 3 positioning mode low
PI17 ...
PI32
See chapter "Auxiliary Drives (Auxiliary Axis)" (see
page 77).
Data word
Bit no.
Description
Process output data word 1
Bit 0
/Controller inhibit
Bit 1
Enable/rapid stop
Bit 2
Enable/stop
Bit 3
Reserved
Bit 4
Reserved
Bit 5
Reserved
Bit 6
Fault reset
Bit 7
Reserved
Bit 8
Start
Bit 9
Jog +
Bit 10
Jog–
Bit 11
Mode selection bit 2
0
Bit 12
Mode selection bit 2
1
Bit 13
Mode selection bit 2
2
Mode:
0: Reserved
1: Jog mode single/group
2: Reference mode single/group
3: Positioning mode single/group
4: Automatic mode group
5: Emergency mode single/group
Bit 14
Reserved
Bit 15
Disable SWLS
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Содержание MOVI-PLC