44
Manual – MOVI-PLC® Application Solution "SyncCrane"
5
Starting the SyncCrane program
Startup
5.3.6
Step 4: Parameters and limits
Parameters and
limits
This window is used to set the limits for travel range and velocity.
672848139
Group
Field
Description
Limit switch
Software LS
CW
The software limit switches limit the permissible travel range for the
"Jog", "Positioning", and "Automatic" operating modes.
The specified value refers to the increments of the synchronous
encoder.
The wizard does not support the activation of hardware limit switches.
Software LS
CCW
Reference
travel
Reference
offset
Enter the reference offset in increments in relation to the synchronous
encoder.
Reference type
The reference travel type defines the movement sequence for detect-
ing the mechanical zero point. You can choose between 3 different
reference travel types.
Type 1
Standstill (individual axis or group drive)
Type 2
Synchronized search travel of the group for right end
reference cam (MOVI-PLC DI00 X31:3)
Type 3
Synchronized search travel of the group for left end
reference cam (MOVI-PLC DI00 X31:3)
Reference
speed 1 and 2
When selecting reference travel type 2 or 3, the cam is searched with
reference travel velocity 1.
Next moving clear of the cam takes place (and then ended) with
reference travel velocity 2.
0
0
I