58
Manual – MOVI-PLC® Application Solution "SyncCrane"
6
Jog mode – unsynchronized
Operation
6.3.1
Supplement jog mode of the virtual axis - synchronized
For documentation of the operating mode, see above. For differences in the interface,
see below.
Mode selection
PO2:Bit11 = TRUE
PO2:Bit12 = FALSE
PO2:Bit13 = FALSE
Prerequisite
All axes are engaged. This is indicated by PI2:4 "Axes
synchronous".
Prerequisite
:
•
"Automatic" mode is selected and "Start" is set via
process data word 1.
•
The axes are enabled (display "A: technology
function" of the 7-segment display)
Jog +
PO2:9
Jog–
PO2:10
Disable SWLS
PO2:15
Velocity specification
PO8 in [rpm] or [user units]
Velocity limit
Startup parameter
Jerk limitation
Startup parameter
Position limiting
Software limit switch startup parameter
Ramp specification
PO9 Acceleration ramp in [ms]
PO10 Deceleration ramp in [ms]
Содержание MOVI-PLC