Manual – MOVI-PLC® Application Solution "SyncCrane"
81
7
Project planning for auxiliary drives
Auxiliary Drive (Auxiliary Axis)
Process input data
words
PI1 = Status word 1
512061835
Bit no.
Description
Bit 0
Motor turning
Bit 1
Frequency inverter ready for operation
Bit 2
IPOS axis referenced
Bit 3
IPOS in position
Bit 4
Brake released
Bit 5
Frequency inverter fault/warning
Bit 6
Limit switch CW
Bit 7
Limit switch CCW
Bit 8 ...
15
Inverter/error status
Process input data word
Profile 1
Pos 16 bit
Profile 2
Pos 32 bit
Profile 3
Velocity
PO1
Status word
Status word
Status word
PO2
Actual speed
Actual speed
Actual speed
PO3
Reserved
Actual position 32 high
Reserved
PO4
Actual position 16
Actual position 32 low
Actual position 16
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Bit 0
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7