Manual – MOVI-PLC® Application Solution "SyncCrane"
87
7
Startup of auxiliary drives
Auxiliary Drive (Auxiliary Axis)
Parameters and
limits
In this window you can set the travel range and velocity limits.
757891723
Group
Field
Description
Limit switch
Software limit switch
CW
The software limit switches limit the permitted travel range for
the following operating modes:
•
Jog
•
Positioning
•
Automatic
The specified value refers to the increments of the
synchronous encoder.
The processing of hardware limit switches is not intended.
Software limit switch
CCW
Hardware limit switches
Choose whether you want hardware limit switches to be
evaluated. They are evaluated on MOVIDRIVE
®
as follows:
•
X13:5 DI04 with /Limit switch CW
•
X13:6 DI05 with /Limit switch CCW
Reference
travel
Reference offset
Enter the reference offset in increments in relation to the
synchronous encoder.
Reference type
The reference type defines the movement sequence for
detecting the mechanical zero point.
Limits
Maximum speed posi-
tioning
You can limit the specified positioning speed by entering the
value.
Maximum speed jog
mode
You can limit the specified jog speed by entering the value.
Maximum motor speed
Enter a value at least 10 % higher than the maximum
positioning and/or jog speed.