Manual – MOVI-PLC® Application Solution "SyncCrane"
61
6
Positioning mode – unsynchronized
Operation
6.5.1
Supplement positioning mode of the virtual axis - synchronized
The following table shows the differences in the interface. Prerequisite is that "Auto-
matic" mode is selected with "Start" set via process data word 1.
Interface description
Mode selection
PO2:Bit11 = TRUE
PO2:Bit12 = TRUE
PO2:Bit13 = FALSE
Prerequisite
All axes are engaged. This is indicated by PI2:4 "Axes synchronous".
Prerequisite
:
•
"Automatic" mode is selected and "Start" is set via process data word
1.
•
The axes are enabled (display "A: technology function" of the 7-
segment display)
Start
PO2:8
Disable SWLS
PO2:15
Position setpoint
PO6 and PO7 in [inc]
Velocity specification
PO8
Velocity limit
Startup parameter
Jerk limitation
Startup parameter
Position limiting
Software limit switch startup parameter
Ramp specification
•
PO9 acceleration ramp
•
PO10 deceleration ramp