Appendix
A.1 Measured variables
SENTRON PAC4200
System Manual, 09/2009, A5E02316180B-02
217
Name
Abbrev.
DE + IEC
Abbrev.
EN + UL
Unit
Dis-
play
LIM
SOURCE
Maximum Harmonics Current c
Maximum fundamental current c
I
1 L3 max
I
1 c max
A
17.1
Maximum value of the current of the fundamental in c
Maximum 3rd harmonic current c
I
3 L3 max
I
3 c max
A
17.1
Maximum 5th harmonic current c
I
5 L3 max
I
5 c max
A
17.1
Maximum 7th harmonic current c
I
7 L3 max
I
7 c max
A
17.1
Maximum 9th harmonic current c
I
9 L3 max
I
9 c max
A
17.1
Maximum 11th harmonic current c
I
11 L3 max
I
11 c max
A
17.1
Maximum 13th harmonic current c
I
13 L3 max
I
13 c max
A
17.1
Maximum 15th harmonic current c
I
15 L3 max
I
15 c max
A
17.1
Maximum 17th harmonic current c
I
17 L3 max
I
17 c max
A
17.2
Maximum 19th harmonic current c
I
19 L3 max
I
19 c max
A
17.2
Maximum 21st harmonic current c
I
21 L3 max
I
21 c max
A
17.2
Maximum 23rd harmonic current c
I
23 L3 max
I
23 c max
A
17.2
Maximum 25th harmonic current c
I
25L3 max
I
25 c max
A
17.2
Maximum 27th harmonic current c
I
27 L3 max
I
27 c max
A
17.2
Maximum 29th harmonic current c
I
29 L3 max
I
29 c max
A
17.2
Maximum 31st harmonic current c
I
31 L3 max
I
31 c max
A
17.2
Maximum value of the current of the 3rd, 5th 7th, … 31st harmonic in c
Average values over all phases
Name
Abbrev.
DE + IEC
Abbrev.
EN + UL
Unit
Dis-
play
LIM
SOURCE
3-Phase Average Voltage ph-n
U
L-N AVG
V
ph-n AVG
V
–
V PH-N DMD.
3-phase average value of the voltage between the phase conductors and the neutral conductor
Maximum 3-phase average voltage ph-n
U
L-N AVG max
V
ph-n AVG max
V
–
Maximum 3-phase average value of the voltage between the phase conductors and the neutral
conductor
Minimum 3-phase average voltage ph-n
U
L-N AVG min
V
ph-n AVG min
V
–
Minimum 3-phase average value of the voltage between the phase conductors and the neutral
conductor
3-Phase Average Voltage ph-ph
U
L-L AVG
V
ph-ph AVG
V
–
V PH-PH
DMD.
3-phase average value of the phase conductor voltages
Maximum 3-phase average voltage ph-ph
U
L-L AVG max
V
ph-ph AVG max
V
–
Maximum 3-phase average value of the voltage between the phase conductors
Minimum 3-phase average voltage ph-ph
U
L-L AVG min
V
ph-ph AVG min
V
–
Minimum 3-phase average value of the voltage between the phase conductors
3-Phase Average Current
I
L AVG
I
ph AVG
A
–
I DMD
3-phase average value of the current in the phase conductors
Содержание PAC4200
Страница 16: ...Introduction 1 6 Further documentation SENTRON PAC4200 16 System Manual 09 2009 A5E02316180B 02 ...
Страница 66: ...Operation planning 4 1 Operation planning SENTRON PAC4200 66 System Manual 09 2009 A5E02316180B 02 ...
Страница 174: ...Service and maintenance 10 6 Disposal SENTRON PAC4200 174 System Manual 09 2009 A5E02316180B 02 ...
Страница 284: ...Index SENTRON PAC4200 284 System Manual 09 2009 A5E02316180B 02 ...