Appendix
A.1 Measured variables
SENTRON PAC4200
System Manual, 09/2009, A5E02316180B-02
207
Name
Abbrev.
DE + IEC
Abbrev.
EN + UL
Unit
Dis-
play
LIM
SOURCE
Maximum THD voltage c
THD
U L3 max
THD
V c max
%
12.1
Maximum total harmonic distortion of the voltage between phase conductor c and the neutral
conductor referred to the fundamental
THD Voltage a-b
THD
U L1-L2
THD
V a-b
%
12.2 THD-V ab
Total harmonic distortion of the voltage between phase conductors a and b referred to the
fundamental
Maximum THD voltage a-b
THD
U L1-L2 max
THD
V a-b max
%
12.3
Maximum THD voltage for a-b referred to the fundamental
THD voltage b-c
THD
U L2-L3
THD
V b-c
%
12.2 THD-V bc
Total harmonic distortion of the voltage between phase conductors b and c referred to the
fundamental
Maximum THD voltage b-c
THD
U L2-L3 max
THD
V b-c max
%
12.3
Maximum THD voltage for b-c referred to the fundamental
THD voltage c-a
THD
U L3-L1
THD
V c-a
%
12.2 THD-V ca
Total harmonic distortion of the voltage between phase conductors c and a referred to the
fundamental
Maximum THD voltage c-a
THD
U L3-L1 max
THD
V c-a max
%
12.3
Maximum THD voltage for c-a referred to the fundamental
THD Current a
THD
I L1
THD
I a
%
13.0 THD-I a
Total harmonic distortion of the current in phase conductor a referred to the fundamental
Maximum THD current a
THD
I L1
THD
I a
%
13.1
Maximum total harmonic distortion of the current in phase conductor a referred to the fundamental
THD current b
THD
I L2
THD
I b
%
13.0 THD-I b
Total harmonic distortion of the current in phase conductor b referred to the fundamental
Maximum THD current b
THD
I L2
THD
I b
%
13.1
Maximum total harmonic distortion of the current in phase conductor b referred to the fundamental
THD current c
THD
I L3
THD
I c
%
13.0 THD-I c
Total harmonic distortion of the current in phase conductor c referred to the fundamental
Maximum THD current c
THD
I L3
THD
I c
%
13.1
Maximum total harmonic distortion of the current in phase conductor c referred to the fundamental
Apparent Energy Tariff 1
E
ap T1
VAh
VAh
18.0
Apparent energy at tariff 1
Apparent energy tariff 2
E
ap T2
VAh
VAh
18.0
Apparent energy at tariff 2
Active Energy Import Tariff 1
E
a T1 imp
Wh
T1 imp
Wh
19.0
Active energy imported at tariff 1
Active Energy Import Tariff 2
E
a T2 imp
Wh
T2 imp
Wh
19.0
Active energy imported at tariff 2
Active Energy Export Tariff 1
E
a T1 exp
Wh
T1 exp
Wh
19.1
Active energy exported at tariff 1
Active Energy Export Tariff 2
E
a T2 exp
Wh
T2 exp
Wh
19.1
Active energy exported at tariff 2
Содержание PAC4200
Страница 16: ...Introduction 1 6 Further documentation SENTRON PAC4200 16 System Manual 09 2009 A5E02316180B 02 ...
Страница 66: ...Operation planning 4 1 Operation planning SENTRON PAC4200 66 System Manual 09 2009 A5E02316180B 02 ...
Страница 174: ...Service and maintenance 10 6 Disposal SENTRON PAC4200 174 System Manual 09 2009 A5E02316180B 02 ...
Страница 284: ...Index SENTRON PAC4200 284 System Manual 09 2009 A5E02316180B 02 ...