Appendix
A.1 Measured variables
SENTRON PAC4200
System Manual, 09/2009, A5E02316180B-02
201
Name
Abbrev.
DE + IEC
Abbrev.
EN + UL
Unit
Dis-
play
LIM
SOURCE
Maximum neutral current
I
N max
I
n max
A
3.1
Maximum value of the current in the neutral conductor
Minimum neutral current
I
N min
I
n min
A
3.2
Minimum value of the current in the neutral conductor
Apparent Power a
VA
L1
VA
a
VA
4.0
VA a
Apparent power in phase conductor a
Maximum apparent power a
S
L1 max
VA
a max
VA
4.1
Maximum value of the apparent power in phase conductor a
Minimum apparent power a
S
L1 min
VA
a min
VA
4.2
Minimum value of the apparent power in phase conductor a
Apparent power b
VA
L2
VA
b
VA
4.0
VA b
Apparent power in phase conductor b
Maximum apparent power b
S
L2 max
VA
b max
VA
4.1
Maximum value of the apparent power in phase conductor b
Minimum apparent power b
S
L2 min
VA
b min
VA
4.2
Minimum value of the apparent power in phase conductor b
Apparent power c
VA
L3
VA
c
VA
4.0
VA c
Apparent power in phase conductor c
Maximum apparent power c
S
L3 max
VA
c max
VA
4.1
Maximum value of the apparent power in phase conductor c
Minimum apparent power c
S
L3 min
VA
c min
VA
4.2
Minimum value of the apparent power in phase conductor c
Active Power a
P
L1
W
a
W
5.0
W a
Active power in phase conductor a as import (+) or export (-)
Maximum active power a
P
L1 max
W
a max
W
5.1
Maximum value of the active power in phase conductor a
Minimum active power a
P
L1 min
W
a min
W
5.2
Minimum value of the active power in phase conductor a
Active power b
P
L2
W
b
W
5.0
W b
Active power in phase conductor b as import (+) or export (-)
Maximum active power b
P
L2 max
W
b max
W
5.1
Maximum value of the active power in phase conductor b
Minimum active power b
P
L2 min
W
b min
W
5.2
Minimum value of the active power in phase conductor b
Active power c
P
L3
W
c
W
5.0
W c
Active power in phase conductor c as import (+) or export (-)
Maximum active power c
P
L3 max
W
c max
W
5.1
Maximum value of the active power in phase conductor c
Minimum active power c
P
L3 min
W
c min
W
5.2
Minimum value of the active power in phase conductor c
Содержание PAC4200
Страница 16: ...Introduction 1 6 Further documentation SENTRON PAC4200 16 System Manual 09 2009 A5E02316180B 02 ...
Страница 66: ...Operation planning 4 1 Operation planning SENTRON PAC4200 66 System Manual 09 2009 A5E02316180B 02 ...
Страница 174: ...Service and maintenance 10 6 Disposal SENTRON PAC4200 174 System Manual 09 2009 A5E02316180B 02 ...
Страница 284: ...Index SENTRON PAC4200 284 System Manual 09 2009 A5E02316180B 02 ...