Appendix
A.1 Measured variables
SENTRON PAC4200
System Manual, 09/2009, A5E02316180B-02
203
Name
Abbrev.
DE + IEC
Abbrev.
EN + UL
Unit
Dis-
play
LIM
SOURCE
Reactive power c (VARn)
Q
n L3
VAR
n c
VAR 6.0
VARn c
Reactive power of the harmonics in phase conductor c referred to the load counting system,
measured according to VARn
Maximum reactive power c (VARn)
Q
n L3 max
VAR
n c max
VAR 6.1
Maximum value of the reactive power of the harmonics in phase conductor c, measured according to
VARn
Minimum reactive power c (VARn)
Q
n L3 min
VAR
n c min
VAR 6.2
Minimum value of the reactive power of the harmonics in phase conductor c referred to the load
counting system, measured according to VARn
Reactive Power a (VAR1)
Q
1 L1
VAR
1 a
VAR 6.0
VAR1 a
Reactive power of the fundamental in phase conductor a referred to the load counting system,
measured according to VAR1
Maximum reactive power a (VAR1)
Q
1 L1 max
VAR
1 a max
VAR 6.1
Maximum reactive power of the fundamental in phase conductor a referred to the load counting
system, measured according to VAR1
Minimum reactive power a (VAR1)
Q
1 L1 min
VAR
1 a min
VAR 6.2
Minimum reactive power of the fundamental in phase conductor a referred to the load counting
system, measured according to VAR1
Reactive power b (VAR1)
Q
1 L2
VAR
1 b
VAR 6.0
VAR1 b
Reactive power of the fundamental in phase conductor b referred to the load counting system,
measured according to VAR1
Maximum reactive power b (VAR1)
Q
1 L2 max
VAR
1 b max
VAR 6.1
Maximum reactive power of the fundamental in phase conductor b referred to the load counting
system, measured according to VAR1
Minimum reactive power b (VAR1)
Q
1 L2 min
VAR
1 b min
VAR 6.2
Minimum reactive power of the fundamental in phase conductor b referred to the load counting
system, measured according to VAR1
Reactive power c (VAR1)
Q
1 L3
VAR
1 c
VAR 6.0
VAR1 c
Reactive power of the fundamental in phase conductor c referred to the load counting system,
measured according to VAR1
Maximum reactive power c (VAR1)
Q
1 L3 max
VAR
1 c max
VAR 6.1
Maximum reactive power of the fundamental in phase conductor c referred to the load counting
system, measured according to VAR1
Minimum reactive power c (VAR1)
Q
1 L3 min
VAR
1 c min
VAR 6.2
Minimum reactive power of the fundamental in phase conductor c referred to the load counting
system, measured according to VAR1
Total Apparent Power
S
VA
VA
7.0
ΣVA
Total apparent power in the phase conductors
Maximum total apparent power
S
max
VA
max
VA
7.1
Maximum value of the total apparent power in the three-phase system
Minimum total apparent power
S
min
VA
min
VA
7.2
Minimum value of the total apparent power in the three-phase system
Total Active Power
P
W
W
7.0
ΣW
Total active power in the phase conductors
Содержание PAC4200
Страница 16: ...Introduction 1 6 Further documentation SENTRON PAC4200 16 System Manual 09 2009 A5E02316180B 02 ...
Страница 66: ...Operation planning 4 1 Operation planning SENTRON PAC4200 66 System Manual 09 2009 A5E02316180B 02 ...
Страница 174: ...Service and maintenance 10 6 Disposal SENTRON PAC4200 174 System Manual 09 2009 A5E02316180B 02 ...
Страница 284: ...Index SENTRON PAC4200 284 System Manual 09 2009 A5E02316180B 02 ...