GL.6
SEL-421 Relay
Date Code 20090715
Glossary
Conditioning Timers
—
Data Attribute
Conditioning Timers
Timers for conditioning Boolean values. Conditioning timers either stretch
incoming pulses or allow you to require that an input take a state for a certain
period before reacting to the new state.
Contact Input
See Control input.
Contact Output
See Control output.
Coordination Timer
A timer that delays an overreaching element so that a downstream device has
time to operate.
Control Input
Relay inputs for monitoring the state of external circuits. Connect auxiliary
relay and circuit breaker contacts to the control inputs.
Control Output
Relay outputs that affect the state of other equipment. Connect control outputs
to circuit breaker trip and close coils, breaker failure auxiliary relays,
communications-assisted tripping circuits, and SCADA systems.
COS Operator
Operator in math SEL
OGIC
control equations that provides the cosine
function.
Counter
Variable or device such as a register or storage location that either records or
represents the number of times an event occurs.
Cross-country fault
A cross-country fault consists of simultaneous separate single phase-to-
ground faults on parallel lines.
CT
Current transformer.
CT Subsidence Current
Subsidence current appears as a small exponentially decaying dc current with
a long time constant. This current results from the energy trapped in the CT
magnetizing branch after the circuit breaker opens to clear a fault or interrupt
load.
CTR
Current transformer ratio.
Current
Reversal Guard Logic
Under this logic, the relay does not key the transmitter and ignores reception
of a permissive signal from the remote terminal when a reverse-looking
element detects an external fault.
Current
Transformer Saturation
The point of maximum current input to a current transformer; any change of
input beyond the saturation point fails to produce any appreciable change in
output.
CVT
Capacitive voltage transformer that uses a capacitive voltage divider to reduce
transmission voltage to a level safe for metering and relaying devices. See
CCVT.
CVT Transient Blocking
Logic that prevents transient errors on capacitive voltage transformers from
causing false operation of Zone 1 mho elements.
CVT Transient
Detection Logic
Logic that detects transient errors on capacitive voltage transformers.
Data Attribute
In the IEC 61850 protocol, the name, format, range of possible values, and
representation of values being communicated.
Содержание 421
Страница 8: ...This page intentionally left blank Courtesy of NationalSwitchgear com ...
Страница 22: ...This page intentionally left blank Courtesy of NationalSwitchgear com ...
Страница 32: ...This page intentionally left blank Courtesy of NationalSwitchgear com ...
Страница 42: ...This page intentionally left blank Courtesy of NationalSwitchgear com ...
Страница 62: ...This page intentionally left blank Courtesy of NationalSwitchgear com ...
Страница 116: ...This page intentionally left blank Courtesy of NationalSwitchgear com ...
Страница 262: ...This page intentionally left blank Courtesy of NationalSwitchgear com ...
Страница 308: ...This page intentionally left blank Courtesy of NationalSwitchgear com ...