SEQUENCER WITH
DIFFERENTIAL PRESSURE
SWITCH
Technical notice
FI 72.0567.0221E
Page 5 / 45
Slaves boxes :
- Supply voltage :
Several versions
Solenoid valves voltage DC
Version supply AC : 100 to 240V
50-60 Hz
Version supply DC : 24Vdc
Solenoid valves voltage AC
115V/230V
10% 50-60 Hz
24V/48V
10% 50-60 Hz
- Consumption max :
Solenoid valves voltage DC
Version supply AC : 1A
Version supply: 2.5A
Solenoid valves voltage AC
5VA + SV consumption
- Number of solenoid valve outputs
18 max
- Electrical connection / cable outlet
3 versions: Individual- multi - Integrated pilots
- Protections :
Solenoid valves voltage AC : see table 1 page 8
Solenoid valves voltage DC : see table 2 page 9
- Solenoid valve voltage:
According to version:
24VDC integrated / Pmax 25W or 40W
24V / 48V / 115V / 230VAC 50-60Hz / Pmax 25VA or 45A
Others on request
- Characteristics of digital inputs:
Voltage: 24VDC supplied by the device
Charge c/- 1mA
- Relay contact characteristics:
dry contact. max: 125VAC / 0.3A - 30VDC / 1A
(to be protected by the user)
- Operating temperature:
-20° to 60°C
Integrated pilot version: 0°C to 60°C
- Storage temperature:
-20° to 70° C
- Case :
Material ABS - IP65
Material PC - IP65 on request
Compressed air pressure measure:
- Scale
0
– 6 Bars
Display accuracy: 0.1Bar
- max pressure
17 Bars
- Precision
1.5% on the maximum sensor scale (10Bars)
→ from 0 to 50 ° C this precision takes into account linearity,
hysteresis, the effects of temperature and repetitiveness
- Humidity
0 to 95% RH
– not condensed
- Output 4-20mA
On request
Integrated power supply, non-isolated - Max load <500 ohms
Note : Read the electrical diagram supplied with the sequencer in order to be aware its configuration and specific