SEQUENCER WITH
DIFFERENTIAL PRESSURE
SWITCH
Technical notice
FI 72.0567.0221E
Page 3 / 45
Overview:
Maximum configuration :
Number of cells: 32
Number of SV per cell: 64 - with a maximum total of 512 SV on the complete filter.
Number of slave boxes: 32
Number of tanks: 32
Number of dust emission probe: 16
Number of digital inputs: 12 (extension possibility)
Number of relay outputs: 6 (extension possibility)
MASTER box/cabinet:
- 7 "touch color HMI
- digital inputs management
- RELAY output management
- analog input / output 4 / 20mA
- integrated dP pressure switch
CUSTOMER communication:
MODBUS RTU protocol - native RS485
On demand :
PROFIBUS, MODBUS TCP / IP,
PROFINET, others ...
PLC /DCS
superviseur
SLAVE boxes: (up to 32)
- Management of up to 18 EV outputs per box
- Integrated Air/Compressed pressure switch
- Cell / tank isolation management
- Cell position control
Dust emission check
- Management of up to 16 dust emission
probes