SEQUENCER WITH
DIFFERENTIAL PRESSURE
SWITCH
Technical notice
FI 72.0567.0221E
Page 2 / 45
SUMMARY :
DESCRIPTION :
The SFX+V2 is an adjustable device for the control and
automatization of declogging equipment, whose declogging is done
by compressed air injections.
It can manage filters organized in several cells (= compartments)
and with several compressed air reservoirs.
Depending on the configuration, declogging is carried out in
ONLINE or OFFLINE mode.
The SFX+V2 manages various controls, such as electric
consumption of SV, position of cell insulation, compressed air
consumption on tanks, dust emissions ...
The SFX+V2 has a historical record of faults and events.
The SFX+V2 incorporates the functional program corresponding
to the configuration of the filter. Adjustment of some parameters can
be done easily on site thanks to the user interface.
The user interface is a multi-lingual 7 "colors touchscreen. Access
is protected at several levels by passwords.
The SFX+V2 has a native RS485 Modbus communication in
order to communicate with the outside (ex: supervision).
It can be adapted to multiple fieldbuses thanks to a gateway also
integrated in the SFX+V2 cabinet.
The SFX+V2, depending of the filter configuration, is composed
of a master box/cabinet and several slave boxes. A configuration in
form of a bus allows, especially, to reduce the wiring compared to a
conventional configuration. In fact, the slave boxes can be placed
near the declogging solenoid valves while collecting the information
necessary for proper declogging (compressed air pressures, cell
position) and by controlling the cell and tank isolation.
For each SFX+V2, an electrical diagram is associated. Refer to it
for connections and dimensions.
Depending on the filter configuration, some parts of this manual
are not used.
Page
- DESCRIPTION
2
- CHARACTERISTICS
Master box/cabinet
Slaves boxes
4
4
5
- CENTRAL UNIT BOARD
6
- SLAVE BOARD
Coding
Protections
7
7
8
- USER INTERFACE
General
Cycle
About
security
HMI
Languages
Parameters
Sequencer / filter configuration
Online shooting sequence
Operating time
Counters
Dust emission
Compressed air
Customer communication
Manual mode
Historical
Faults
Events
Current faults
10
10
11
12
13
14
15
16
17
22
24
26
27
28
29
30
31
32
34
36
OPERATION
Putting in service
Online
Offline
37
37
38
39
- FAULT CHECK
Electrical faults
Mini pressure faults
re-inflation tank faults
SV non-opening faults
Dust emission faults
Link faults
Cell opening / closing faults
Other faults
40
40
40
41
41
42
43
43
43
- PRECAUTIONS
44
- WARRANTY
44
- CERTIFICATE
44
- GENERAL INSTRUCTIONS OF
SAFETY, ASSEMBLY,
COMMISSIONNING AND
MAINTENANCE
45
- ANNEX