XCA 1100 / XCA 1200 Control Unit
Operating Manual XCA 1100 / XCA 1200
●
Version 12/17
25
CNC/PLC properties
PLC
processing
times every
1000
instructions
Bit
0.064 ms
Byte / Word / DWord
0,033 ms
Integer (Add / Mul)
0,038 ms
Real (Add)
0.064 ms
PLC signal propagation time (input to
output)
< 2 ms (for task periods = 1 ms)
Function blocks
Any number of firmware functions and function
blocks
Number of NC axes / sub-systems
64 / 32
CNC interpolation cycle from
1 ms
Block cycle time from
1 ms
Operating
system
Controller
VxWorks, multitasking operating system (time-
driven / priority-driven)
PLC runtime
ProConOS
PC
Windows Embedded
Configuring
MULTIPROG acc. to IEC 61131-3
Number of user tasks
18
Task cycle times
Programmable
≥ 1 ms (whole number)
Real-time
memory
(can be set)
Operating system
(data / program)
32768 kB
PLC memory
Programs
4096 kB
Flag retentive
256 kB
Flag not retentive
2048 kB
Memory management
Dynamic
Times and counters
Any number programmable from 1 ms ... 290 h
(number limited only by memory capacity)
Dimensions / weight
Dimensions (W x H x D)
142 mm x 200 mm x 150 mm
Modular spacing
4
Weight
2500 g
The information in chapter "Technical Data of all Modules", page 147
also applies.