Technical Data for Control Unit XCA
Electrical data
Internal power supply
DC 12 V, DC 5 V, DC 3.3 V
Internal power consumption
< 40 W
Isolation
(from internal
electronics)
X1, X2, X3 Ethernet
Yes
X4, X5 Sercos III
Yes
X6/7, X8/9 USB
No
X10 DVI
No
X11 CAN
Yes
X12 (RS 422)
Yes
X12 (RS 232)
Yes
Interfaces
Ethernet
RJ 45
Programming, diagnosis and operating panel
interface
Sercos III
RJ 45
Sercos III drive interface (Ethernet)
USB
Standard A
USB interface (e.g. mouse, keyboard, USB
memory stick)
DVI
DVI-I single link
Monitor interface (DVI-I)
CAN
10-pin plug-in
terminal
CANopen field bus interface
RS 232
10-pin plug-in
terminal
for stationary connection of serial units
RS 422
10-pin plug-in
terminal
Serial operating panel interface
Hardware and memory
Processor
Performance versions
Different processors, up to Core i7, are possible.
Memory
SDRAM
512 MB to 4 GB
SRAM (buffered)
1 MB
Solid state drive
32 GB / 64 GB
Real-time clock
Battery-buffered with calendar and leap year,
resolution: 1s
Buffering
Supercap min. 3 hours,
rechargeable battery after at least of 4 hours
charge time, min. 3 months.