SATEL ACU-280
21
7.3 Device settings
ARU
[Use ARU-100] – parameter available for a wireless device, if the ARU-200 repeater is
registered in the controller (the controller is connected to the INTEGRA or INTEGRA Plus
control panel). It allows you to define whether the device is to communicate to the
controller directly, or via the selected ARU-200 repeater (several ARU-200 repeaters can
be registered in the controller).
Always active
[Active mode] – the option is available for the most of wireless detectors. If
enabled, the detector is permanently switched over to the active mode (see „Wireless
detectors” p. 29).
The wireless detectors assigned to 24-h zones are always in the active mode,
therefore the “Always active” option does not have to be enabled for them.
The battery life time in the detectors switched permanently into the active mode is
shorter than in those which are periodically switched to the passive mode.
Configuration
[Settings] – for some devices you can configure additional parameters and
options. Shown in parentheses is the device name in the ABAX 2 system (if the device is
identified in the alarm system by the name known from the ABAX system). Shown in
square brackets is information about the number of zone for which additional parameters
are to be programmed if the device takes up more than one zone.
ADD-200
– wireless outdoor dusk and temperature detector. You can configure:
sensitivity of the dusk sensor (detection threshold) [first zone],
temperature parameters [second zone]:
threshold type: high (when the temperature rises above the defined value, alarm
will be triggered) or low (when the temperature drops below the defined value,
alarm will be triggered),
temperature,
tolerance.
AGD-100 (AGD-200)
– wireless glass-break detector. You can configure sensitivity.
AMD-100 (AMD-200)
/
AMD-101 (AMD-201)
– wireless magnetic contact. Do not
configure the detector settings (the AMD-200 / AMD-201 detector does not have two
reed switches).
AMD-102 (AMD-202)
– wireless magnetic contact with input for roller shutter detector:
do not configure the magnetic contact settings [first zone] (the AMD-202 detector
does not have two reed switches).
you can configure parameters of roller shutter input [second zone]:
number of pulses after which the roller shutter input will trigger alarm,
time period during which the defined number pulses must occur for the roller
shutter input to trigger alarm.
AOCD-250 (AOCD-260)
– wireless outdoor dual technology curtain detector. You can
configure:
sensitivity of the PIR sensor,
sensitivity of the microwave sensor.
AOD-200 (AOD-210)
– wireless outdoor dual technology motion detector. You can
configure:
sensitivity of the PIR sensor,
sensitivity of the microwave sensor,