31
The EN50131-3 standard requires that zones must react to signals lasting more than
400 ms. Therefore, select 400 ms when programming sensitivity of the alarm zones.
Information on the state of zones and commands to change the state of outputs are sent
immediately. Zone settings are sent during periodical communication.
If communication with the controller is lost, all previously activated outputs will be
deactivated after 20 communication periods.
If the ACX-220 expander is powered from a power supply unit connected to the APS
connector, the low battery information provided by the control panel means:
first zone – power supply overload,
second zone – low battery,
third zone – AC mains loss.
7.4.4 Wireless 230 V AC controllers
Turning on the output to which the controller is assigned turns on the relay controlling the
230 V AC circuit (turns on power).
The zone to which the wireless controller is assigned is activated when the relay controlling
the 230 V AC circuit is turned on [operating modes 1 and 2] / ASW-200 controller button is
pressed [operating mode 0] / ASW-210 controller input is activated [operating mode 0] (select
the appropriate zone type).
7.4.5 Radio signal repeater
The first zone to which the radio signal repeater is assigned is activated in the event of
230 V AC mains loss (select the appropriate zone type).
The second zone to which the radio signal repeater is assigned is activated in the event of
battery trouble (select the appropriate zone type).
If tamper of the radio signal repeater is to trigger tamper alarm, program the zone as
2EOL/NC or 2EOL/NO.
8
APT-200 keyfobs
The number of supported keyfobs depends on the number of control panel users.
Before adding a keyfob that was previously registered to the ABAX / ABAX 2 system,
you must restart it (to do so, long press the
and
buttons for 30 seconds or
remove the battery for 30 seconds).
The data related to keyfobs are stored in the controller. After the controller containing
keyfob data is connected to the control panel, keyfobs will be automatically assigned
to the existing users.
8.1 Keyfobs in the INTEGRA / INTEGRA Plus system
If two or more ABAX / ABAX 2 controllers are connected to the control panel, the keyfob will
be supported by all of them. The keyfobs data are written automatically to all the controllers.
If you connect a controller to the INTEGRA 128-WRL control panel or a control panel to
which an ABAX / ABAX 2 controller is already connected, the APT-200 keyfobs data must be
unified. You can do it using:
DLOADX program – in the “Keyfobs ABAX” window, click on the “Read” button and,
immediately after the data are read, click on the “Write” button (after reading the data, you
must not make any changes),