SATEL ACU-280
33
8.1.1 Keyfob management using the DLOADX program
You can manage the keyfobs in the “Keyfobs ABAX” window (Fig. 12). The window opening
command is available in the “Users” menu. Before making any changes, click on the “Read”
button, and after making the changes – on the “Write” button (the data related to keyfobs are
not read and saved after clicking on the
button in the program main menu).
Adding a keyfob
Entering the serial number manually
1. Click on the field in the “S/N” column next to the name of the user to whom you want to
assign a keyfob.
2. Enter the keyfob serial number and press ENTER.
Reading the serial number during transmission
1. Click on the field in the “S/N” column next to the name of the user to whom you want to
assign a keyfob.
2. Click on the “New” button.
3. The “New” window will open.
4. Press the keyfob button.
5. When the keyfob serial number is displayed in the window, click on the “OK” button.
6. The “New” window will close.
7. The serial number of the new keyfob will be shown in the “S/N” column.
Assigning a zone to keyfob button (combination of buttons)
1. Click on the field corresponding to the button (combination of buttons).
2. Enter the zone number and press ENTER.
3. Using the SPACE key enable/disable the event generating function. If the
symbol is
displayed next to the zone number, the event will not be saved after pressing the button /
combination of buttons (if no symbol is displayed, the event will be saved).
Assigning outputs to the LEDs
1. Click on the field in the “LED” column.
2. Using the keyboard, enter up to 3 digits. Each of the digits must correspond to the number
of field with output selected for confirmation (on the window right side) i.e. it can be from
the 1 to 8 range. The names of outputs in fields designated with these digits will be shown
in bold-type face.
Removing a keyfob
1. Click on the field in “S/N” column next to the name of user whose keyfob is to be
removed.
2. Click on the “Delete” button.
3. The “Confirm” window will open.
4. Click on the “Yes” button.
5. The “Confirm” window will close.
6. The keyfob serial number shown in the “S/N” column will be erased.
8.2 Keyfobs in the VERSA / VERSA Plus / VERSA IP system
The functions which can be started using the keyfobs and the information that can be
presented on the LEDs are described in manuals for the VERSA / VERSA Plus / VERSA IP
control panels.