28 ACU-280
SATEL
5. Enter a digit from the 1 to 3 range to define sensitivity (1 – low, 2 – medium, 3 – high).
6. Press .
7. When the pet immunity settings are displayed, press (these settings are irrelevant).
APMD-150 (APMD-250)
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Define whether the detector is to be always active by pressing any number key ( – no,
– yes).
4. Press .
5. Enter a digit from the 1 do 4 range to define sensitivity of the PIR sensor (1 – minimum;
4 – maximum).
6. Press .
7. Enter a digit from the 1 do 8 range to define sensitivity of the microwave sensor
(1 - minimum; 8 – maximum).
8. Press .
9. Use the
and
keys to select how the detector will work in the test mode (PIR+MW,
PIR or MW).
10. Press .
ARD-100 (ARD-200)
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Define whether the detector is to be always active by pressing any number key ( – no,
– yes).
4. Press .
5. Enter a number from the 1 to 16 range to define sensitivity (1 – minimum; 16 – maximum).
6. Press .
ASD-150 (ASD-250)
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Press any numeric key to define whether the detector is to signal alarm from other
ASD-250 detectors ( – no, – yes).
4. Press
.
5. Press any numeric key to define whether the detector is to send out alarm to other
ASD-250 detectors ( – no, – yes).
6. Press .
AVD-100 (AVD-200)
For the magnetic contact:
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Define whether the detector is to be always active by pressing any number key ( – no,
– yes).
4. Press .
5. When the reed switch settings are displayed, press (these settings are irrelevant).