SATEL ACU-280
9
AUX CLK DTA COM
VERSA
+12V COM CKE DTE
ACU-280
+VR DTA CLK COM
VERSA Plus
VERSA IP
+12V COM CKE DTE
ACU-280
Fig. 7. Method of connecting the controller to the VERSA / VERSA Plus / VERSA IP control
panel.
If you use the twisted-pair type of cable, remember that the DTM and CKM / CKE and DTE
(clock and data) signals must not be sent through one pair of twisted conductors. The
conductors must be run in one cable.
4.6 Connecting the power supply and starting the controller
1. Connect the power cables to the +12V and COM terminals. The controller may be
powered directly from the control panel or from a power supply unit with current limitation
up to 3 A.
2. Replace the cover.
3. Turn the power on. The LED indicator should come on.
4. Run the identification function in the control panel (see the control panel installer manual).
The controller will be identified as ACU-100.
5
Wireless devices supported by the controller
The ABAX 2 wireless devices are divided into 3 categories:
devices,
keypads,
keyfobs.
For each of these categories a separate pool of positions is provided in the controller.
5.1 Devices
Detectors
ADD-200
- wireless outdoor dusk and temperature detector.
AGD-200
- wireless glass-break detector.
AOCD-260
- wireless outdoor dual technology curtain detector.
AOD-210
- wireless outdoor dual technology motion detector.
APD-200
- wireless passive infrared detector.
APD-200 Pet
- wireless passive infrared detector with pet immunity up to 20 kg.
APMD-250
- wireless dual technology motion detector.
ASD-200
- wireless smoke and heat detector.