SATEL ACU-280
29
For the shock detector:
1. Enter a digit from the 1 to 8 range to define sensitivity (1 – minimum; 8 – maximum).
2. Press .
3. When the settings regarding the number of shocks are displayed, press (these settings
are irrelevant).
ASP-100 (ASP-200)
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Use the
and
keys to select the type of acoustic signaling (see table 5).
4. Press .
5. Use the
and
keys to define the maximum duration of signaling.
6. Press .
ASP-205 (ASP-215)
You can program two different ways of signaling:
having selected the first of the zones – signaling triggered by the first output controlling the
siren,
having selected the second of the zones – signaling triggered by the second output
controlling the siren.
Configuration is similar for both zones, however, the step in which the rules of device
presence control are defined is skipped for the second zone.
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Use the
and
keys to define how the acoustic signaling will work ( – disabled; 1, 2
or 3 – type of acoustic signaling – see table 6).
4. Press .
5. Use the
and
keys to define the maximum duration of signaling.
6. Press .
7. Define whether the optical signaling is to be enabled ( – no, – yes).
8. Press .
ASW-100 (ASW-200)
1. Enter a number from the 0 to 50 range to define the rules of device presence control.
2. Press .
3. Use the
and
keys to define the way of control (“inactive” – only remote control;
“interim control” – remote or manual control; “combined control” – remote or manual
control, but with option to manually block the remote control).
4. Press .
7.4 Specific character of the operation of wireless devices
When configuring the alarm system zones and outputs to which the wireless devices are
assigned, you must take into account the specific character of operation of individual devices.
7.4.1 Wireless detectors
The zone to which a wireless detector is assigned is activated when the detector reports
alarm (select the appropriate zone type). If a detector tamper is to trigger the tamper alarm,
program the zone as 2EOL/NC or 2EOL/NO.