12 ACU-280
SATEL
list and then added to the system again, so as to fill up the gap in the list and reduce the
number of zones reserved for wireless devices.
In case of devices which, in addition to zones, also take up outputs, it is recommended that
you add them to the system first. This will allow you to maintain the continuity of use of not
the zones alone, but the outputs as well.
In some cases, the gaps in the list of zones/outputs cannot be avoided. It applies to situation
when the number of zones/outputs, which is used by the devices, is not a multiple of 8.
For each group of 8 zones/outputs, one address on the expander bus is reserved. The
controller can occupy from 1 to 6 addresses. This must be taken into account at the system
design stage and sufficient number of free addresses must be left for the controller. If, when
new wireless devices have been added to the controller, it turns out that next addresses are
needed, and these are taken up by other devices, successful completion of the expander
identification procedure will be impossible. It will be necessary to change addresses of the
devices connected to the bus.
INTEGRA / INTEGRA Plus
ACU-220
zones
outputs
It.
list of devices
No
device
No
device
1 APD-200 detector
17 APD-200 detector
17 unused/unavailable
2 APD-200 detector
18 APD-200 detector
18 unused/unavailable
3 AMD-200 detector
19 AMD-200 detector
19 unused/unavailable
4 AMD-200 detector
20 AMD-200 detector
20 unused/unavailable
5 AMD-201 detector
21 AMD-201 detector
21 unused/unavailable
6 ^
22 AMD-201 detector
22 unused/unavailable
7
23 unused/unavailable
23 unused/unavailable
8 ASP-200 siren
8
24 ASP-200 siren
24 ASP-200 siren
9 ^
25 ASP-200 siren
25 ASP-200 siren
10
26 unused/unavailable
26 unused/unavailable
11
27 unused/unavailable
27 unused/unavailable
12
28 unused/unavailable
28 unused/unavailable
13
29 unused/unavailable
29 unused/unavailable
14
30 unused/unavailable
30 unused/unavailable
15
31 unused/unavailable
31 unused/unavailable
16
8
32 unused/unavailable
32 unused/unavailable
Table 3.
INTEGRA / INTEGRA Plus
ACU-220
zones
outputs
It.
list of devices
No
device
No
device
1 ASP-200 siren
17 ASP-200 siren
17 ASP-200 siren
2 ^
18 ASP-200 siren
18 ASP-200 siren
3 APD-200 detector
19 APD-200 detector
19 unused/unavailable
4 APD-200 detector
20 APD-200 detector
20 unused/unavailable
5 AMD-200 detector
21 AMD-200 detector
21 unused/unavailable
6 AMD-200 detector
22 AMD-200 detector
22 unused/unavailable
7 AMD-201 detector
23 AMD-201 detector
23 unused/unavailable
8 ^
8
24 AMD-201 detector
24 unused/unavailable
Table 4.