- 190
Mini ECO-i System
Remote Control Functions
7
13. Serial-Parallel I/O Unit
(ACC-SP16TAG(B))
30
10
1.0
3.0 V
SW3
SW2
SW1
ON
1
2
3
4
5
6
7
8
5
6
OFF OFF
ON OFF
OFF ON
1
2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
ON
OFF
1 2
ON
OFF
1 2
ON
OFF
1 2
ON
OFF
1 2
1
2
3
16
17
18
19
32
33
34
35
48
49
50
51
64
G
G
CX
COM
+24V
CX
TX
CX
COM
+24V
COM
+24V
D i gi t al
i n pu t
D i gi t al
i n pu t
D i gi t al
i n pu t
Example circuit
Isolating terminal
Terminal number
12P-1
12P-2
12P-4
12P-5
12P-6
12P-7
12P-11
12P-12
12P-8
12P-9
12P-8
12P-9
12P-10
12P-3
B(+)
A(-)
B(+)
A(-)
Name
Digital
input/output
terminal
Analog
input/output
Input/
output item
Status
output
Control
input
Analog
output
*3
Analog
input
*2
Input/output conditions
Start output
Alarm output
No-voltage a-contact
static
No-voltage a-contact
static
Allowable contact
voltage and current:
DC 30 V, 0.5 A
(Minimum load: 1 V, 1 mA)
Allowable contact
voltage and current:
DC 30 V, 0.5 A
(Minimum load: 1 V, 1 mA)
Allowable contact
voltage and current:
DC 30 V, 0.5 A
(Minimum load: 1 V, 1 mA)
COS output (answerback)
Filter sign output
Start input
Stop input
Voltage a-contact
pulses
Allowable contact
voltage and current:
DC 24 V, 10 mA
Allowable contact
voltage and current:
DC 24 V, 10 mA
Central input
Voltage a-contact
static
Allowable contact
voltage and current:
DC 24 V, 10 mA
Voltage a-contact
static
Emergency stop input
Indoor temperature
monitor output
Output current:4 to 20 mA
Temperature indication range:
Input impedance:250
Input impedance:1M
Remote controller sensor:
Remote controller
On-the-body sensor:
Air intake temperature
Indoor temperature
setting input
Input voltage:1 to 5 V
Temperature setting range:
Within the indoor
temperature setting range
Detector
Modulator
Modulator
Insulated
analog
input
Input/Output
Condition
ON with
a filter sign
Pulse width:
300 msec or
longer
Remote contr-
oller disabled
on rising and
enabled on
falling of static
input
Operation
stopped and
remote controller
disabled on rising
and remote contr-
oller enabled on
falling of static
input
Analog outputs
for 16 units are
provided. Use
insulated
individual
analog input.
Analog inputs
for 16 units are
provided. Use
within 0.1%
of reference
accuracy
CPEV0.9
1.2
CPEV0.9
1.2
CPEV0.9
1.2
CPEV0.9
1.2
CPEV0.9
1.2
CPEV0.9
1.2
CPEV-S0.9
1.2
CPEV-S0.9
1.2
(3) Connecting the Serial-Parallel I/O Unit with the Remote Stations
The length of a wire that connects a Serial/Parallel I/O unit and the
equipment should be less than 50 m for analog signal, and less than
100 m for digital signal.
*1 About Emergency Stop Signal
This signal immediately stops all indoor units connected to the
Serial/Parallel I/O unit and disables any manual operations through the
remote controller. When this signal is off, manual operations through
remote controllers become enabled.
*2 About Temperature Setting Input (analog input)
When the setting signal for room temperature is within DC1 - 5 V, the
setting value is sent to the applicable group, and each air conditioner in
the group sets a setting temperature within a predetermined range for
the air conditioner. Temperature is indicated in 1°C intervals. Check the
precision (resolution) of the central monitor. When a signal more than
1.0 V is inputted, temperature setting can not be carried out with the
remote controller that shows the sign, "Under Centralized Control". With
a signal less than 1.0 V, temperature setting can be made with the
remote controller.
Enable the remote controller
to set temperature
Disable the remote controller
from setting temperature
4. About Setting Switches and Display
Changing of the disabled mode of
remote controller temperature setting
Digital circuit board
Main circuit board
Spare
T
est
Alarm delay switch
Centralized mode
Connection confirmation
Monitor
Speed
Zone
Setting
Central Address System Indoor
(Code Date 1 Data 2)
Setting
display
Back Forward Set Cancel
Setting
Button
About Setting Switches (SW1)
About Setting of SW2 and SW3
Spare switch: Be sure that all switches are turned off to use.
Switch No8 Test
Mode
Be sure to use
the unit with the
switch turned off.
Switch No 4
Switching of a main unit and a sub unit
under centralized control
Main unit: OFF Sub unit: ON
For normal use, the main unit is turned
off. In use with the AMY adaptor, the
intelligent controller, and the system
controller, turn on the sub unit.
Switch No 7
Spare
Be sure to use the
unit with the
switch turned off.
Switch No 3
Spare
Be sure to use
the unit with the
switch turned off.
Central control address registration switch
Switch No.
Switch No.
Normal mode
Manual Central control
address registration :
Auto Central control
address registration :
Zone address switch
Zone address
1 (Central control address 1-16)
2 (Central control address 17-32)
3 (Central control address 33-48)
4 (Central control address 49-64)
Central control address 1-16
Central control address 17-32
Central control address 33-48
Central control address 49-64
5. Zone Address Setting Switch of Serial-Parallel I/O
When controlling the Serial/Parallel I/O units in two or more zones, set the
zone address for each unit (setting switches No. 1 and 2 on SW1).
To control a Serial/Parallel I/O unit in only one zone, adjust the setting of
the unit for Zone 1.
To control Serial/Parallel I/O units in two or more zones, adjust the setting
of one of the Serial/Parallel I/O units for Zone 1.
Turn on the main powers of all air conditioners.
After completing test run of the air conditioners, set central control
addresses as follows.
Serial/Parallel I/O SW1
Zone1
Zone2
Zone3
Zone4
6. Setting Procedure for Central Control Address
Set central control addresses automatically?
(Central control addresses will be automatically set in increasing order of Unit No.)
Automatic setting
Manual setting
1.Automatic registration
of central control
addresses by
Serial-Parallel I/O:
C2
2.Manual registration of
central control
addresses:
C1
3.Registration of central
control addresses
through the wired
remote controller
Set addresses through the wired remote controller?
Central control
addresses are manually
set through
Serial-Parallel I/O.
Central control
addresses are manually
set through the wired
remote controller.
Carry out each input after the display return to the normal mode, and
check the operating status of each air conditioner. The number shown on
the setting display is the central control address and the Unit No. of the air
conditioner.
*3 About the Room Temperature Monitor (analog output)
The current of the room temperature monitor signal is within DC4 - 20
mA (5 - 35 ). And temperature is indicated in 0.5 intervals. Check the
precision (resolution) of the central monitor.
Response
time for
start/stop
input:
Max.40
seconds
Response
time for
start/stop
input:
Max.1
second
*1
5 to 36 , 0.5 step
Temperature reading:
In steps of 1
Analog
output
1
8
1
8
1
8
Serial-Parallel I/O Unit side
Remote Station side
06-408 Mini_ECOi_SM7 11/10/06 7:25 PM Page 190
获取更多资料
微信搜索蓝领星球
Содержание 85402843
Страница 28: ...3 MEMO 06 408 Mini_ECOi_SM3 11 10 06 5 19 PM Page 4 获 取 更 多 资 料 微 信 搜 索 蓝 领 星 球 ...
Страница 32: ...4 MEMO 06 408 Mini_ECOi_SM4 11 10 06 5 56 PM Page 4 获 取 更 多 资 料 微 信 搜 索 蓝 领 星 球 ...
Страница 200: ...获 取 更 多 资 料 微 信 搜 索 蓝 领 星 球 ...
Страница 205: ...获 取 更 多 资 料 微 信 搜 索 蓝 领 星 球 ...
Страница 252: ...200611M DC 获 取 更 多 资 料 微 信 搜 索 蓝 领 星 球 ...