Maintenance
SY26U Excavator OMM
5-34
Operation and Maintenance Manual — 1119
SANY
Replace the Hydraulic Tank Breather Filter Element
1. Prepare the machine for service. See “Maintenance
2. Open the right access door.
3. Clean around the hydraulic tank breather assembly (4).
4. Remove the wing nut cover (1) and press the relief
valve button (2) to release pressure in the hydraulic
tank.
5. Remove and clean the cover (3).
6. Inspect the filter element (5). Replace the filter element
as needed.
7. Install the filter. Tighten the cover and wing nut cover
securely.
WARNING!
•
Allow the hydraulic system to cool before servicing. Hot oil may cause burns or other
serious injury.
•
The hydraulic tank may be under pressure, and hydraulic oil may be present at the filler
cover. Relieve any pressure to prevent injury.
Failure to follow these warnings could result in death or serious injury.
NOTICE!
Dispose of the used filter in accordance with all
applicable environmental regulations. Failure to
do so could result in damage to the
environment.
Fig. 5-21
0003126
2
1
4
3
Fig. 5-22
0003127
5