SY26U Excavator OMM
Maintenance
SANY
Operation and Maintenance Manual — 1119
5-31
T
ABL
E OF
CONT
E
N
TS
INTRODUCTION
SAFE
T
Y
MACHIN
E
CONTROLS
MACHINE
OP
ERA
T
IO
N
MA
INTENANCE
SPEC
IFI
CA
TIO
N
S
OP
T
IO
N
A
L
EQUI
PMENT
Remove the Battery
1. Prepare the machine for service. See “Maintenance Safety” on page 2-8.
2. Open the right access door and turn the battery disconnect switch to OFF. See “Battery Disconnect Switch” on
3. Disconnect the ground terminal (1) first, followed by
the positive terminal (2).
4. Remove the battery clamp fastener (3) and
battery clamp.
5. Check that all cables and parts are out of the way, then
lift the battery out of the battery compartment.
6. Clean the battery tray.
7. Installation is in the reverse order of removal. Connect
the positive terminal first, followed by the ground
terminal.
WARNING!
Before proceeding with any battery maintenance procedure, follow and remember these
points:
•
Battery gases are explosive. Never smoke around batteries or expose them to sparks or
open flames.
•
Wear personal protective equipment when working with batteries.
•
Work in a well-ventilated area.
•
If battery acid contacts skin or eyes, flush the area immediately with fresh water and seek
medical attention.
Failure to observe and follow this warning could result in death or serious injury.
NOTICE!
After machine shutdown, wait at least 1 minute for the engine control module (ECM) to
complete its shutdown before disconnecting the battery. Failure to observe and follow this
notice can damage the machine or cause it to operate improperly.
Fig. 5-19
0003235
2
1
3