INSTALLATION GUIDE
MODULAR SUNWAY TG
TE OD
Rev. 03
– 01/06/2018
27/
139
AC
Modules
DC
Modules
MPPTs
1
2
1
The DC modules are connected to
each other on DC side. In this mode,
only one module (Master) performs
MPPT function, while the other
modules operate on the setpoint set
by the master module.
Configuration featuring
triple converter, multi-master
AC
Modules
DC
Modules
MPPTs
1
3
3
Each DC section is connected to its
own
independent
array.
Each
conversion
module
operates
independently and performs the
MPPT function. The PV arrays may
have
different
features
and
installation requirements.
Configuration featuring
triple converter, hybrid configuration
AC
Modules
DC
Modules
MPPTs
1
3
2
Two DC sections are connected in
Master/Slave mode, whilst the third
section operates in Master mode,
independently of the other two
sections.
Configuration featuring
quadruple converter, multi-master
AC
Modules
DC
Modules
MPPTs
1
4
4
Each DC section is connected to its
own
independent
array.
Each
conversion
module
operates
independently of each other and
performs the MPPT function. Arrays
may have different features and