![Santerno SUNWAY TG1200 1000V TE OD Скачать руководство пользователя страница 130](http://html1.mh-extra.com/html/santerno/sunway-tg1200-1000v-te-od/sunway-tg1200-1000v-te-od_installation-manual_810313130.webp)
MODULAR SUNWAY TG
TE OD
INSTALLATION GUIDE
130/
139
Rev. 03
– 01/06//2018
No.
Name
Description
I/O Features
DIP-switch
1
CMA
0V for main reference (connected to
control 0V).
0V control board
2
REF
Analogue input which can be configured
as a voltage input or current input
Analogue input available for the Power
Control function if configured as a voltage
input.
Vfs = ±10 V
Rin: 50 k
Resolution: 12 bits
SW1-1: Off
0 (4)
– 20 mA
Rin = 250
Resolution: 11 bits
SW1-1: On
3
-10VR
Negative -10 V power supply output
-10 V
Imax: 10 mA
4
+10VR
Po10 V power supply output
+10V
Imax: 10 mA
5
AIN1+
Analogue grid voltage input.
Vfs = ±10 V
Rin: 50 k
Resolution: 12 bits
SW1-2: Off
6
AIN1-
n/a
SW1-2: On
7
AIN2+
Analogue grid voltage input.
Vfs = ±10 V
Rin: 50 k
Resolution: 12 bits
SW1-3: Off
SW1-4.5: Off
8
AIN2-
n/a
SW1-3: On
SW1-4.5: Off
9
CMA
0V for auxiliary inputs (connected to
control 0V).
10
AO1
Delivered active power fed back to AO1
analogue output.
Please refer to the Programming Guide.
Vout = ±10 V
Ioutmax = 5 mA
Resolution: 11 bits
SW2-1: On
SW2-2: Off
0 (4)
– 20 mA
Voutmax = 10 V
Resolution: 10 bits
SW2-1: Off
SW2-2: On
11
AO2
Field voltage fed back to AO2 analogue
output.
Please refer to the Programming Guide.
Vout = ±10 V
Ioutmax = 5 mA
Resolution: 11 bits
SW2-3: On
SW2-4: Off
0 (4)
– 20 mA
Voutmax = 10 V
Resolution: 10 bits
SW2-3: Off
SW2-4: On
12
AO3
Field current fed back to AO3 analogue
output.
Please refer to the Programming Guide.
Vout = ±10 V
Ioutmax = 5 mA
Resolution: 11 bits
SW2-5: On
SW2-6: Off
0 (4)
– 20 mA
Voutmax = 10 V
Resolution: 10 bits
SW2-5: Off
W2-6: On