![Santerno SUNWAY TG1200 1000V TE OD Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/santerno/sunway-tg1200-1000v-te-od/sunway-tg1200-1000v-te-od_installation-manual_810313128.webp)
MODULAR SUNWAY TG
TE OD
INSTALLATION GUIDE
128/
139
Rev. 03
– 01/06//2018
TG 1800 1500V TE
X10 7-8
AC
Module
50-60 Hz
Table 49: Technical data for power supply from UPS
12.8.6. String box power supply
When the String Box option is present, a power supply line for the Smart String Boxes is available.
Inverter Model
Terminals
Voltage /
Frequency
Available
power
[VA]
Minimum
cable
cross-
section
[mm
2
]
Maximum
cable cross-
section
[mm
2
]
TG 610 1000V TE
X10 9-10
AC module
230Vac 50-
60Hz
500
0.5
2.5
TG 900 1500V TE
TG 1200 1000V TE
X10 9-10
AC module
230Vac 50-
60Hz
1000
0.5
2.5
TG 1800 1500V TE
Table 50: Technical data for power supply from UPS
12.8.7. Input/Output signals connection
Inverter Model
Terminal board
Minimum cable
cross-section [mm
2
]
Maximum cable cross-
section [mm
2
]
ALL
X6, AC module
0.5
2.5
Table 51: Signal cable technical data
12.8.8. Environmental inputs connection
Inverter Model
Terminal board
Minimum cable
cross-section [mm
2
]
Maximum cable cross-
section [mm
2
]
ALL
X10, DC module
0.5
2.5
Table 52: Environmental inputs technical data
12.9.
PV-Side SPD Specifications
The technical specifications for SPDs are provided in the table below.
Technical specifications
1000V TE
1500V TE