User manual SNC-637ID
_________________________________________________________________________________
- 11 -
2.3
DIP Switch Setup
Before installing the camera, set up the DIP switch to configure the camera ID and
the communication protocol.
Camera ID Setup
ID numbers of cameras are set up with binary numbers. See the
examples shown below.
Pin
1
2
3
4
5
6
7
8
Binary Value
1
2
4
8
16
32
64
128
ex) ID=5
on
off
on
off
off
off
off
off
ex) ID=10
off
on
off
on
off
off
off
off
The camera ID range is “1~255”.
Camera ID must not be “0”!
The facto
ry default of the camera ID is “1”.
Match the camera ID with the Cam ID setting of your DVR or
Controller to control the camera.
If you are connecting a single camera to a controller, terminate the
camera. When connecting more than one camera to a single
controller, terminate the last camera on the communication line.
The last camera means the camera farthest in cable length from
the controller.
Note that the total length of the communication cable betweena
controller and the camera(s) on the same communication line
must be less than 1.2Km.
ON
ON
1
2
3
4
5
6
7
8