BLAST CHILLER ISTRUCTION
05/2014
7 ALARMS LIST
Note: Faults probes
Once the sensor is replaced, the alarm di-
sappears after 10 seconds. The sensor alarms at -50°C are disa-
bled during freezing at -18°C and during the ice cream
hardening function. Where not specified, each alarm is accom-
panied by a buzzer (if present). The sound made is a five second
beep that is repeated every 15 seconds. The label indicating the
alarm in progress is alternately displayed with the current display.
ALL
Er1
Cell sensor failure
Cause:
Outside of operating range
(-50°C / +100°C) for more than 30 seconds with a
blast chilling temperature cycle in progress.
Effect:
In standby it prevents startup of blast chilling/
freezing.
In blast chilling/freezing and storage, the cycle is
not blocked and the compressor is activated in cy-
cles (according to the parameters)
Reset:
check connections and operation of the
cell sensor
ALL
Er2
Evaporator Sensor Failure
(only if evaporator sensor is enabled)
Cause:
Outside of operating range
(-50°C / +100°C) for more than 30 seconds with a
blast chilling temperature cycle in progress.
Effect:
In standby, blast chilling/freezing
and storage, there is no effect.
Any defrost will end due to a timeout.
Reset:
check connections and operation of the evapora-
tor sensor
ALL
Er3
Product Probe Failure
Cause:
Outside of operating range
(-50°C / +100°C) for more than 30 seconds with a
blast chilling temperature cycle in progress.
Effect:
In standby it prevents startup of temperature con-
trolled blast chilling/freezing. In temperature con-
trolled blast chilling/freezing it causes a change
over to a timed cycle. In storage, there is no effect.
Reset:
Check connections and operation of the product
probe.
ALL
AL1
Door Open Alarm
Effect:
In standby and defrost there is no effect. For the
effects on the compressor and fan, see parameters.
Reset:
close the door, verify the micro door operation
ALL
AL2
High Pressure Alarm
Effect:
In standby there is no effect.
In blast chilling/freezing and storage it blocks the
cycle and the panel returns to standby
Reset:
eliminate the cause of the alarm, turn the panel off
and back on.
ALL
AL4
Probe not inserted alarm
Cause:
failure to insert the probe inside the product du-
ring execution of temperature controlled blast
chilling
Effect:
The display shows alarm AL4, the temperature
icon
e
flashes and the buzzer sounds
Reset:
Insert the probe and restart the temperature cycle
using the button
t
.
To proceed without the probe, start a timed cycled
using the button
y
.
If no choice has been made after the alarm has
been sounding for one minute, the machine will
automatically start a temperature cycle.
ALL
BLC
Blackout Alarm
Cause:
following a power interruption, the machine is in
blackout alarm
Effect:
the machine goes into standby or storage mode if
the machine is in blast chilling mode when the
blackout occurs, the set cycle will restart and the
display will show the BLC alarm alternating with
the blast chilling settings. The buzzer sounds every
3 seconds
Reset:
To silence the alarm, press the
u
button.
ALL
S
XX
Temperature Alarm
Cause:
The blast chiller doesn't reach the set temperature in
the time expected during blast chilling/freezing
Effect:
The cycle continues and doesn't go into storage
mode, the display shows the alarm followed by
the temperature, and the buzzer sounds for 3 se-
conds and then repeats after a minute
ALL
Ht
High Temperature Alarm
Cause:
the cell sensor (only during storage) detects a tem-
perature above the set parameters for a certain
amount of time.
Effect:
The display shows the Ht alarm alternating with a
temperature value, the buzzer sounds for 3 seconds
every 30 seconds.
ALL
rtc
Clock error
Reset the date and the real time (see item 4.2).
ALL
Er[
Interface error
Cause :
User interface – control module compatibility error
Solutions:
Check the user interface control module compatibi-
lity (check the data given on the labels)
Effect :
The control module will continue to operate regu-
larly
ALL
ErL
Interface error
Cause :
User interface – control module communication
error
Solutions:
Check the user interface control module connection
Effect :
The control module will continue to operate regu-
larly
When the cause triggering the alarm disappears, the instrument re-
stores normal operation, except for the clock error (
rtc
code),
which requires the date and time to be set.
i