SAMES KREMLIN
Page 33
Manual : 573.176.112
Chart of the internal parameters ModBus address in RAM
D
e
s
c
ri
p
ti
o
n
U
s
a
b
le
M
o
d
b
u
s
F
u
n
c
ti
o
n
s
A
c
c
e
s
s
T
y
p
e
B
y
te
s
h
e
ig
h
t
H
C
1
2
A
d
d
re
s
s
M
o
d
b
u
s
A
d
d
re
s
s
C
o
m
m
e
n
ta
ry
Analog inlet 8
3 / 4
RO
2
0x102E
0x817
Reading of the compressed
analog inlet 8 of the sensor and
electronic offsets (sensor point
12 bits)
TOR outlets
3 / 4
RO
2
0x101E
0x80F
Reading of the 16 outlets of the
card
Fault 0 (the
most recent
with date)
4 bytes
3 / 4
RO
4
0x1030
0x818
The structure of Fault is a word
of 32 bits, the 24 bits of strong
weight give the instant, (copy of
time meter at the moment of the
apparition in second), and the 8
bits of weak weight give the
number of fault (0xFF indicates
no fault)
Fault 1
3 / 4
RO
4
0x1034
0x81A
Idem above
Fault 2
3 / 4
RO
4
0x1038
0x81C
Idem above
Fault 3
3 / 4
RO
4
0x103C
0x81E
Idem above
Fault 4
3 / 4
RO
4
0x1040
0x820
Idem above
Fault 5
3 / 4
RO
4
0x1044
0x822
Idem above
Fault 6
3 / 4
RO
4
0x1048
0x824
Idem above
Fault 7
3 / 4
RO
4
0x104C
0x826
Idem above
Fault 8
3 / 4
RO
4
0x1050
0x828
Idem above
Fault 9
3 / 4
RO
4
0x1054
0x82A
Idem above
Fault 10
3 / 4
RO
4
0x1058
0x82C
Idem above
Fault 11
3 / 4
RO
4
0x105C
0x82E
Idem above
Fault 12
3 / 4
RO
4
0x1060
0x830
Idem above
Fault 13
3 / 4
RO
4
0x1064
0x832
Idem above
Fault 14
3 / 4
RO
4
0x1068
0x834
Idem above
Fault 15 (the oldest
one)
3 / 4
RO
4
0x106C
0x836
Idem above
Weight of
reference A
3 / 4,6 and 16
RWL
4
0x1070
0x838
For your information only
Coefficient of
weight A
3 / 4,6 and16
RWL
4
0x1074
0x83A
For your information only
Mini weight check
A
3 / 4,6 and16
RWL
4
0x1078
0x83C
For your information only
Maxi weight check
A
3 / 4,6 and 16
RWL
4
0x107C
0x83E
For your information only