SAMES KREMLIN
Page 15
Manual : 573.176.112
10- ADJUSTMENT OF PARAMETERS
LIST OF PARAMETERS
Test parameters are entered at the factory before the control unit is delivered.
Each parameter value is given a nominal for the first start up.
PARAMETER
N°
SPECIFICATION
MINI
LIMIT
MAXI
LIMIT
VALUE FOR THE
FIRST
OPERATING
01
Type of Interface
01
04
04
02
Maximum system pressure (bar)
10.0
150.0
50
03
Lower piston Limit position (mm)
1.0
50.0
11
04
Maximum filling time cycle (sec)
10.0
99.9
99.9
05
Top piston position after Filling (mm)
00.0
50.0
5
06
Minimum Pressure during the filling (bar)
00.0
25.0
2
07
Servo-control gain during the filling cycle (see
definition below)
01
99
10
08
Servo-control gain regulation during the dispensing
cycle (see definition below)
01
99
10
09
Preset for low level piston position during pre
pressurising stage (in mm)
00.0
50
8
10
Allowable Pressure Tolerance between pre
pressurised material and start of extrusion (% bar)
01
20
10
11
Electronic filter to control any interfefence from
Regulex or Robot
01
20
10
12
Time duration for bead profile modification during
production (in ms)
01
20
10
13
Servo control gain during bead profile modification (%)
01
99
10
14
Maxi flow coefficient (%)
01
99
10
15
Material Preset flow rate during manual application
(0-10V)
00.0
99.9
10
16
Language choice (Fr.: 1; IT.: 2; Engl.: 3; Spa.: 4)
1
3
1
17
Material density (%)
25
400
100
18
Regulex® piston section (mm2)
01
4000
2205
19
Weight tolerance alarm (%)
01
20
5
20
Simulation internal value of the external instruction
00
99.9
10
21
Configuration parameter for RS 232 connection
5
22
Configuration parameter for RS 485 connection
6
23
Response address of the ModBus slave
1
127
2
24
Pressure sensor scale
10
250
50
25
Position sensor scale
10
100
25
26
Exhaust valve version
0
1
0