6- OPERATING OF A REGULEX® SYSTEM
To operate the REGULEX®, you must :
-
Set the offsets (see 'Page offsets - § 12 ),
-
Check the parameter values and modify them if necessary (see 'Page parameters - § 10').
Parameters are entered at the factory before the control unit is released for delivery.
We give each parameter a nominal value for the first start up. (see parameter settings).
Warning : Some parameters will only correspond to specific REGULEX® models.
Parameters values can always be modified to ensure optimum operating of the REGULEX® system.
PRIMING
This function is performed using
manual
operating mode
(MANU page).
- Press the
EXTRUSION
{2} button until the REGULEX® piston reaches its lower position.
- Release the
EXTRUSION
key.
- Pressurize the material supply pump (from 0 to 6 bar / from 0 to 87 psi) and the valves on the shot
meter to (6 bar / 87 psi) :
The material inlet and outlet valves of the REGULEX® proportioning gun are open.
- Press the
PRIMING/FILLING
{3} key.
The material is pumped through the hoses into the REGULEX® metering chamber.
Material will flow out of the REGULEX® outlet valve, allow the material to continue flowing for 1 to 2
minutes to purge any air from the system : the REGULEX® is now primed.
- Press the
PRIMING/FILLING
{3} key again
The Priming cycle is completed, the REGULEX® valves are closed.
REGULEX® FILLING
Display on the screen '
AUTO MODE
' {1}.
The 'FILLING' LED is “
ON”
, the REGULEX® chamber is filling with material.
When the filling cycle is finished :
The 'READY' LED “will Illuminate”and the 'FILLING' LED “goes out”.
MANUAL DISPENSING
-Display on the screen '
MANU MODE
' {1}.
At the end of the filling operation, the REGULEX® piston is in the upper position, the system measures,
checks, regulates the piston position, the pressure in the chamber, and the flow instructions.
- Press the 'EXTRUSION' key :
The outlet valve opens, and the REGULEX® dosing piston descends down the metering chamber as
programmed
Material Bead Dispensing
At the end of the dispensing cycle, a display on the screen will appear '
AUTO MODE
' {1} and the
REGULEX® will refill ready for the next cycle.