SAMES KREMLIN
Page 6
Manual : 573.176.112
4- INSTALLATION
DESCRIPTION OF THE LABEL MARKINGS
SAMES KREMLIN
STAINS FRANCE
Name and address of the manufacturer
PN
Product reference
SN
Number given by SAMES KREMLIN.The first 2 numbers indicate the
year of manufacture
-
-
-
-
-
Supply voltage in alternative / Frequence / Amperage
(ex : 1 AC 230V / 50Hz / 3A)
Install the B6 control unit in a place where the power supply can’t be disconnected, for example, in a
quiet room.
Use connection terminals for a fixed equipment connected with a power cable that follows a protected
process.
Place a feeder disconnector upstream of the equipment, with a higher gauge (order of magnitude : 10A..
16A) with a short circuit current of some kiloamperes.
The control unit must be firmly mounted so that it is not affected by vibration.
At the rear part of the B6 control unit:
Connect the cables between the B6 control unit and the REGULEX® shot meter:
- Regulex® (15-pins socket, HARTING)
- Encoder (6-pins socket, JAEGER)
- Motor (4-pins socket, JAEGER)
Connection between the B6 control unit and most robots (12-pins socket, JAEGER: INTERFACE UNIT)
NOTA: due to the wide range of options we do not include this in our scope of sale