SAMES KREMLIN
Page 12
Manual : 573.176.112
SIGNALLING - INDICATING LIGHTS
The B6 control unit is fitted with 5 LEDS :
1 -
'POWER ON'
LED (green).
2 -
'FAULT'
LED (red) indicating a fault and the REGULEX® has stopped
3 -
'FILLING'
LED (orange) indicating that the REGULEX® is going to be filled.
4 -
'EXTRUSION'
LED (green) indicating that the system is in extrusion stage.
5 -
'READY'
LED (green) indicating that the REGULEX® is filled and ready to
dispense.
Nota :
The LEDS (FILLING, READY, EXTRUSION) are functions in automatic mode only.
7- SHUTDOWN OF THE REGULEX® SYSTEM
SHUTDOWN FOR MORE THAN 5 MN
The REGULEX® dosing valve must return to rest position (home).
A
NO
flow must be programmed.
Place the nozzle in a receptacle of compatible plasticiser (or inert material).
EXTENDED SHUTDOWN (EXAMPLE : NIGHT)
Carry out the previous stages.
Turn the 'O-I' switch located on the front of the control panel to the 'O' position and turn off the power
(input during 1 second) but leave the control unit (cabinet) switched on.
Turn off the compressed air supply to the pump system.
Leave the compressed air supply ON to the REGULEX® valve.
STARTING UP
Turn ON the air supply to the pump system.
Switch on the REGULEX® control panel by turning ON the 'O-I' switch.
From the REGULEX® control panel, purge (PRIMING sequence) the REGULEX® shot meter before
continuing an automatic cycle (starting production).