SAMES KREMLIN
Page 25
Manual : 573.176.112
Offset patching procedure - How to calibrate
The unit must be 'switched on', but not 'in service'.
The variable speed drive must not be supplied 'with power'.
The REGULEX® proportioning machine must
not be pressurised.
Release any residual material pressure from the supply pump - the material hose - and the REGULEX®
shot meter.
Pressure Sensor Calibration :
Select 'Sensor pressure Regulex A'
a display : xx bar / xx psi will show
xx bar / xx psi is the pressure that the sensor is measuring.
The value of this pressure must be within ± 4 bar i.e (-4 bar / 59 psi and +4 bar / 59 psi) to make the
calibration possible (if the pressure sensor is outside these values then it is faulty and should be
replaced).
RECORD THE PRESSURE SHOWN & ENTER
xx bar / xx psi +
key
pressure 0
Position offset patching :
Select sensor position Regulex A
display :
xx mm
By means of a screwdriver, lift up the end of the
potentiometer (13) that is on the lubricator (28)
and raise it to the top of the light.
The value of that position must be contained in
0 to + 4mm to make the validation possible
(otherwise, fault of the movement sensor).
xx mm +
key
position 0
Important :
Stroke length of Regulex® shot meters position
sensors :
- REGULEX® Compact Monoblock shot meter:
Stroke D = 69,5 mm
- REGULEX® Divorced shot meter Stroke D =
123 mm
Example above :
Dosing machine, version compacted 5cc